First, a brief description:
Electric (manual) ray protection door: mainly used for x, γ ray and neutron beam shielding (160KV, 200KV, 250KV, 300KV, 400KV, 450KV, cobalt-Co60, 銥-192), its structure is steel + lead composite structure. The lead door can be divided into double-door open door and single-door door. The transmission mode is electric and manual. The electric door can be made into two modes: upper drive and lower drive according to installation conditions and user requirements. The body size is customized according to the user's actual radiation dose level and door opening size. The product technology is advanced and exquisitely made. The electric ray protection door is also equipped with safety devices such as door chain, work indicator light and ionizing radiation sign.
Second, the protective door material selection:
The electric ray protection door is also selected according to the needs of the user, and is made of a steel plate rivet welded structure, a protective material such as a protective coating or a lead plate. It is suitable for the protection of high radiation doses of work detection, nuclear energy room, radiation source library and other gates. It is an essential product for radiation protection of industrial inspection and exposure room. The protection quality of electric ray protection door produced by the company fully meets the national protection quality standard.
Third, the characteristics:
The flat driveway does not need to be disconnected, and the gate and the flat car can be easily operated. People and cars and forklifts can directly enter and exit to meet the industrial x-ray inspection and health protection standard "GBZ117-2002".
The protective door is beautiful in appearance, flexible in operation, light in weight and durable.